Binder | Model CB-260 | CO₂ incubator

Download

Binder | Model CB-260 | CO₂ incubator

Binder 

Model CB-260 | CO₂ incubator with hot air sterilization and heat sterilizable CO₂ sensor

Binder Test Cihazları Türkiye Distribütörü | Enfor

 

Optimized humidification system with condensation protection
Tried-and-tested anti-contamination concept with 180 °C hot air sterilization
Hot-air sterilizable CO₂ sensor with single-beam infrared technology
Seamless inner chamber made of stainless steel
Fanless interior with flanges as shelf support system
Intuitive touchscreen controller with Venturi CO₂ gas mixing nozzle
Internal data recording can be read out in open format via USB interface
Fault diagnosis system with visual and acoustic alarm
Interfaces: Ethernet, USB, zero-voltage alarm contact
Fail-safe CO₂ system for protecting the pH of cell cultures

 

Description CB260-230V * CB260-230V-O * CB260UL-120V * CB260UL-120V-O *
         
Article Number 9640-0013 9640-0014 9640-0015 9640-0016
Performance Data Temperature        
Temperature range +4 °C above ambient temperature to [°C]        
Temperature range +5 °C above ambient temperature to [°C] 60   60  
Temperature range +6 °C above ambient temperature to   60 °C   60
Temperature variation at 37 °C [± K] 0.4 0.4 0.4 0.4
Temperature fluctuation at 37 °C [± K] 0.1 0.1 0.1 0.1
Recovery time after 30 seconds door open at 37 °C [min] 6 6 6 6
Performance Data Climate        
Humidity range 90…95 90…95 90…95 90…95
CO₂-Data        
CO₂ range [Vol.-% CO₂] 0…20 0…20 0…20 0…20
CO₂ measurement IR IR IR IR
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] 5 5 5 5
O₂-Data        
Standard O₂ control ranges: O₂ range [Vol.-% O₂]   0.2…20   0.2…20
O₂ control ranges with option: O₂ range [Vol.-% O₂]   10…95   10…95
O₂ Recovery time after 30 seconds door open at 5 Vol.-% O₂ [min]   15   15
O₂ Recovery time after 30 seconds door open at 10 Vol.-% O₂ [min]        
Electrical data        
Rated Voltage [V] 200…230 200…230 100…120 100…120
Power frequency [Hz] 50/60 50/60 50/60 50/60
Nominal power [kW] 1.5 1.5 1.5 1.5
Unit fuse [A] 10 10 16 16
Phase (Nominal voltage) 1~ 1~ 1~ 1~
Measures        
Interior volume [L] 267 267 267 267
Net weight of the unit (empty) [kg] 125 125 125 125
Permitted load [kg] 40 40 40 40
Load per rack [kg] 10 10 10 10
Wall clearance back [mm] 100 100 100 100
Wall clearance sidewise [mm] 50 50 50 50
Internal Dimensions        
Width [mm] 620 620 620 620
Height [mm] 750 750 750 750
Depth [mm] 575 575 575 575
Doors        
Inner doors 1 1 1 1
Unit doors 1 1 1 1
Housing dimensions not incl. fittings and connections        
Width net [mm] 740 740 740 740
Height net [mm] 1020 1020 1020 1020
Depth net [mm] 785 785 785 785
Environment-specific data        
Energy consumption at 37 °C [Wh/h] 65 65 65 65
Sound-pressure level [dB(A)] 41 41 41 41
Fixtures        
Number of shelves (std./max.) 3/8 3/8 3/8 3/8