Chamber Furnaces for Annealing, Hardening and Brazing up to 1280 °C
Model |
Tmax |
Inner dimensions in mm |
Volume |
Outer dimensions1 in mm |
Connected |
Electrical |
Weight |
Heating time |
||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
in °C |
w |
d |
h |
in l |
W |
D |
H |
load in kW |
connection* |
in kg |
in min2 |
Nabertherm N 7/H Model Laboratuvar Fırını |
1280 |
250 |
250 |
140 |
9 |
800 |
650 |
600 |
3.0 |
1-phase |
60 |
320 |
Nabertherm N 11/H Model Laboratuvar Fırını |
1280 |
250 |
350 |
140 |
11 |
800 |
750 |
600 |
3.5 |
1-phase |
70 |
320 |
Nabertherm N 11/HR Model Laboratuvar Fırını |
1280 |
250 |
350 |
140 |
11 |
800 |
750 |
600 |
5.5 |
3-phase3 |
70 |
70 |
Nabertherm N 17/HR Model Laboratuvar Fırını |
1280 |
250 |
500 |
140 |
17 |
800 |
900 |
600 |
6.4 |
3-phase3 |
90 |
110 |
Nabertherm N 31/H Model Laboratuvar Fırını |
1280 |
350 |
350 |
250 |
31 |
1040 |
1100 |
1340 |
15.0 |
3-phase |
210 |
90 |
Nabertherm N 41/H Model Laboratuvar Fırını |
1280 |
350 |
500 |
250 |
41 |
1040 |
1250 |
1340 |
15.0 |
3-phase |
260 |
105 |
Nabertherm N 61/H Model Laboratuvar Fırını |
1280 |
350 |
750 |
250 |
61 |
1040 |
1500 |
1340 |
20.0 |
3-phase |
400 |
105 |
Nabertherm N 87/H Model Laboratuvar Fırını |
1280 |
350 |
1000 |
250 |
87 |
1040 |
1750 |
1340 |
25.0 |
3-phase |
480 |
105 |
To withstand harsh use in the laboratory, e.g. when heat-treating metals, robust insulation with light refractory bricks is necessary. The chamber furnaces N 7/H - N 87/H are a perfect fit to solve this problem. The furnaces can be extended with a variety of accessories, like annealing boxes for operation under protective gas, roller guides, or a cooling station with a quench tank. Even high-performance applications like the annealing of titanium in medical applications can be implemented without the use of expensive and complicated annealing systems.
Standard Equipment
Tmax 1280 °C
Deep furnace chamber with three-sides heating: from both side walls and bottom
Heating elements on support tubes ensure free heat radiation and a long service life
Bottom heating protected by heat-resistant SiC plate
Temperature uniformity up to +/− 10 °C according to DIN 17052-1
Low energy consumption due to multi-layer insulation
Base frame included in the delivery, N 7/H - N 17/HR designed as table-top model
Parallel guided downward swinging door (user protected from heat radiation)
Door movement cushioned with gas dampers/struts
Controller B400 (5 prgrams with each 4 segments)
Defined application within the constraints of the operating instructions
NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive